Automatically combines batteries during charging, isolates batteries when discharging and when starting engines
Features
Protects sensitive electronics by temporary isolation of house loads from engine circuit during engine cranking
Designed for 12 or 24 volt systems
12/24 volt auto-ranging voltage input
Hermetically sealed contacts/vapor proof
Ignition protected—safe for installation aboard gasoline powered boats
Supports high-output alternators up to 120 Amperes
Dual sensing
Optional Features
Start Isolation allows temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics from sags and spikes
Remote LED remotely indicates ACR states – requires optional LED
£152.50 Original price was: £152.50.£127.08Current price is: £127.08.
Specifications
Nominal Voltage
12V DC24V DC
Start Isolation*
Yes
Amperage Operating Current
175mA (combined)15mA (open)
Terminal Stud Torque
140 in-lb (15.82 Nm)
Continuous Rating**
120A
Intermittent Rating***
210A (5 min)
Cable Size to Meet Ratings
1/0 AWG
Stud Material
Tinned Copper
Terminal Ring Diameter Clearance
1.12in (28.45 mm)
Terminal Stud Length
0.875in (22.23 mm)
Terminal Stud Size
3/8″ – 16 (M10)
Relay Contact Position
Combine 30 sec
13.6V @ 12 V27.2V @ 24 V
Combine 90 sec
13.0V @ 12 V26.0V @ 24 V
Open 10 sec
12.35V @ 12 V24.7V @ 24 V
Open 30 sec
12.75V @ 12 V25.5V @ 24 V
Open High
16.0V @ 12 V30.0V @ 24 V
Over Voltage Lockout
16.0V @ 12V32.0V @ 24V
Under Voltage Lockout****
9.5V @ 12 V19V @ 24 V
Weight
1.25lb (0.57 kg)
*Condition: Engine starting
Relay is open isolating batteries
Batteries are isolated to protect sensitive electronics from voltage sags and spikes
**The maximum current a switch is designed to conduct for an indefinite period.
***The maximum amount of current a switch is designed to carry for a minimum of a designated period of time.
****As a safety feature, some ACRs prevent combining into a severely discharge battery. A dual-sensing ACR will monitor the voltage on both batteries and will not connect if either battery is below the undervoltage lockout level. Use caution when combining into a battery with extremely low voltage, because this might represent a faulty battery or a problem elsewhere in the system.
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
A detailed answer to provide information about your business, build trust with potential customers, or help the visitor with a problem they may be encountering
This is a gallery to showcase images from your recent social posts
41 Buckden Road, Brampton, Cambridgeshire, PE28 4PR
T: +44 77 71 854 787 E: info@Chandlery-Online.com
© DfSMarketplace Ltd 2024